In accordance with customers' actual needs, FANTY Machinery offers two techniques of modification:
1. Handle the uncoiler's automated start and stop using the opposite-beam photoelectric sensor switch. The height at which the uncoiler must start and stop is where the opposite-beam photoelectric switch is mounted. The photoelectric switch controls the uncoiler's stop when the uncoiler material sags to a point where it blocks the opposing beam. When the material is taken out of the opposing light's position, the machine that follows can start up again.
2. To regulate the uncoiler's automated start and stop, utilize the micro switch. Place the micro switch in the waiting area for the feeder, the leveler that comes next, and the uncoiler. Secure it with a floor bracket. The micro switch transmits a control signal to the intermediate relay in the uncoiler box, instructing it to stop the uncoiler's motor when the uncoiler tape sags and comes into contact with it.